Have an emergency?

No problem. We are also available after business hours via our emergency cell phone. Contact us for any emergency service.

T +49 5066 90333-0
emergency(at)helmke.de 

 

Highlights

6 MW HELMKE FULL LOAD TEST FIELDTo meet customers requirements and HELMKE's aspiration to work always with state of the art technologies, the HELMKE Group has invested in a new testing field on its location in Pulversheim, France. The testing field is also available for final customer inspections and external testing orders.[ [more] ]

HELMKE 24/7 DELIVERY PROGRAM 5 MW SOFTSTARTER AVAILABLE FROM STOCKThe HELMKE group, with a heritage of motor and generator sales/stock­ keeping/production going back more than 90 years, is continuously investing in its production facilities and its extensive stock. [ [more] ]

INFRARED MEASURING FOR THERMOGRAPHIC ANALYSIS IN MAINTENANCE, SERVICING AND REPAIRDuring normal operation electrical components and mechanical bearing parts are warming up but are protected against overheating by constructive measures. In case of failure typical local hotspots occur which may lead to consequential damages but these can simply be identified by thermal analysis. [ [more] ]

6 MW HELMKE full load test field

To meet customers requirements and HELMKE‘ s aspiration to work always with state of the art technologies, the HELMKE Group has invested in a new testing field on its location in Pulversheim, France. The testing field is also available for final customer inspections and external testing orders.

Please click here:

Please download: HELMKE Flyer System Test Field

Relevant technical data


Power-, voltage- and frequency range

  • Maximum testing capacity of 6000 kW (8000 HP) for mains and operation and combined testing within a speed range of 500 to 4000 rpm.
  • Maximum torque of approx. 120 kNm (88.500 lbf ft) for speed ranges up to 500 rpm.
  • Voltage range from 400 V up to 15 kV (higher voltages possible on demand)
  • Supply frequency-standard value 50/60 Hz
    (Other frequency values on request)

Testing foundation

  • Fixing plate of 21 m x 6 m (69 ft x 20 ft) (slot T42)
  • Foundation weight of 900 metric tons with reduced resonance frequency (mounting independent from environmental infrastructure)

Water cooling system

  • Maximum re-cooling power of 1150 kW depending on the application
  • Water-quantity and pressure individually adaptable to the machines to be tested
  • Possibility to supply the machines to be tested with specific cooling water quality

Application

Power-, development- and acceptance testing with reference to current regulations and standards resp. customer specific requirements:

  • Motors and generators for main operation
  • Drive systems consisting of transformers, frequency converters, starter and electrical machines
Sitemap   Ι   Imprint   Ι   Legal notice   Ι   General terms and conditions